Abstract
Medical device–related pressure injuries are a significant and largely preventable patient safety problem, yet existing pressure injury risk scales do not adequately capture device-specific risk factors in adults. This methodological study developed and psychometrically evaluated a standardized risk assessment scale to identify medical device–related pressure injury risk in hospitalized adult patients. An initial item pool was generated from an extensive literature review and clinical expertise, and content validity was assessed by seven experts using the Davis technique (content validity index = 0.96). The scale was administered to160 adults receiving at least one medical device in medical, surgical and oncology wards and intensive care units of a university hospital. Construct validity was evaluated using binary logistic regression, exploratory factor analysis, and receiver operating characteristic curve analysis, demonstrating strong discrimination (area under the curve = 0.844, 95% confidence interval 0.728–0.961) with an optimal cut-off score of 14.5 (sensitivity 70.6%, specificity 88.8%). Exploratory factor analysis of the final version of the MedRAS (Kaiser-Meyer- Olkin = 0.792) revealed a two-factor structure (Device and Mechanical Factors; Patient and Tissue Factors) explaining 50.92% of the total variance, with all factor loadings above 0.30. The scale showed good internal consistency(Cronbach's alpha = 0.80) and very good inter-rater reliability (Cohen's kappa = 0.806, p < 0.001). This device-focused scale maysupport early risk identification and targeted preventive nursing interventions, with potential to improve patient safety and qual-ity of care in inpatient/critical care settings.
Notes
Open Access Details:
This is an open access article originally published under the terms of a Creative Commons License, which permits the Sigma Repository to post a copy in its collections. The license is attached to this item record; please click on the license for further details.
Original Article Citation:
A. Karadağ, A. Uçanbelen, and Ö. E. Dalli, “ Development and Psychometric Evaluation of a Medical Device–Related Pressure Injury Risk Assessment Scale,” International Wound Journal 23, no. 4 (2026): e70918, https://doi.org/10.1111/iwj.70918.
No changes have been made to this article.
Sigma Membership
Non-member
Type
Article
Format Type
Text-based Document
Study Design/Type
Other
Research Approach
Quantitative Research
Keywords:
Instrument Construction, Instrument Validation, Psychometrics, Pressure Ulcer, Risk Assessment, Scales--Evaluation
Recommended Citation
Karadag, Ayise; Uçanbelen, Aleyna; and Erbay Dalli, Öznur, "Development and Psychometric Evaluation of a Medical Device-Related Pressure Injury Risk Assessment Scale" (2026). Individual Articles. 50.
https://www.sigmarepository.org/individual_articles/50
Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License
Publisher
Wiley Blackwell
Version
Publisher's Version
Rights Holder
All rights reserved by the author(s) and/or publisher(s) listed in this item record unless relinquished in whole or part by a rights notation or a Creative Commons License present in this item record. All permission requests should be directed accordingly and not to the Sigma Repository. All submitting authors or publishers have affirmed that when using material in their work where they do not own copyright, they have obtained permission of the copyright holder prior to submission and the rights holder has been acknowledged as necessary.
Review Type
External Review: Previously Published Material
Acquisition
Indexed Previously Published Material (Per Creative Commons License)
Date of Issue
2026-07-24
Full Text of Presentation
wf_yes