Abstract

Purpose: Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are potentially life-threatening diseases, most of which are occult in occurrence, with complex and variable clinical symptoms. Intra-abdominal pressure (IAP) measurement has become a recognized practice in the field of critical care. However, the repeatability, safety, and credibility of these measurement techniques remain unclear. The aim of this study is to provide a comprehensive overview on emerging direct and alternative methods for intra-abdominal pressure (IAP) measurement techniques.

Methods: This was a scoping review study following Arksey and Malley's framework. The PubMed, EMBASE, Web of Science, EBSCO, Scopus and ProQuest databases were searched, and studies published between 2000 and 2023 inclusive were considered. All identified studies were reviewed by two reviewers through article title and abstract screening. Full-text articles were assessed based on the inclusion criteria. Original studies that reported on the development, feasibility and credibility of IAP measurement techniques were included.

Results: Forty-two of 9954 screened articles were included. IAP measurement techniques include three major categories: direct, indirect (including the transvesical, transgastric, transrectal, transfemoral vein and intravaginal methods) and less invasive measurement techniques (the abdominal wall tension measurement method, microwave reflectometry, the ultrasonographic method and the measurement system for pressurized vessels). Agreement analyses were performed in most studies, and some explored the safety, time expenditure and reproducibility of IAP measurement techniques.

Conclusion: Clinical data assessing the validation of new IAP measurement techniques or the reliability of established measurement techniques remain lacking. At present, there are still many shortcomings in direct and alternative methods for IAP measurement. Intrarater reliability of intravaginal transducers has not been evaluated, while the transrectal and transfemoral vein methods have not be proven to be feasible and credible. Abdominal wall tension method still need be standardized to obtain more reliable and repeatable evaluations. Transvesical method is the potentially most credibility and easy applicable technique fo

Notes

The presenters have authored a published journal article on this topic. The article is not located in this repository, but the citation is provided for information purposes.

Li, Z., Wang, H., & Lu, F. (2024). The development, feasibility and credibility of intra-abdominal pressure measurement techniques: A scoping review. PLoS ONE, 19(3), 1–13. https://doi.org/10.1371/journal.pone.0297982

Partial reference list below. Additional references available in attached slide deck.

Jacobson N, Driscoll M. Validity and reliability of a novel, non-invasive tool and method to measure intra-abdominal pressure in vivo. J Biomech. 2022;137: 111096.

Van Stappen J, Pigozzi C, Tepaske R, Van Regenmortel N, De Laet I, Schoonheydt K, Dits H, Severgnini P, Roberts DJ, Malbrain ML. Validation of a novel method for measuring intra-abdominal pressure and gastric residual volume in critically ill patients. Anaesthesiol Intensive Ther. 2014;46(4): 245-254.

David M, Raviv A, Guttel A, García Reyes V, Simini F, Pracca F. Non-invasive indirect monitoring of intra-abdominal pressure using microwave reflectometry: system design and proof-of-concept clinical trial. J Clin Monit Comput. 2021;35(6):1437-1443.

Description

The repeatability, safety, and credibility of existing IAP measurement techniques still remain unclear. In this scoping review, we provided a comprehensive and broad overview of the current and emerging direct and alternative methods for IAP measurement.

Author Details

ZhiRu Li, BSN1; HuaFen Wang, MN2; FangYan Lu, MN2

(1) Zhejiang University School of Medicine, hangzhou, ZheJiang, China

(2) First Affiliated Hospital, Zhejiang University School of Medicine, hangzhou, China

Sigma Membership

Non-member

Type

Presentation

Format Type

Text-based Document

Study Design/Type

Other

Research Approach

Other

Keywords:

Intra-Abdominal Pressure, Pressure Measurement, Critically Ill

Conference Name

35th International Nursing Research Congress

Conference Host

Sigma Theta Tau International

Conference Location

Singapore

Conference Year

2024

Rights Holder

All rights reserved by the author(s) and/or publisher(s) listed in this item record unless relinquished in whole or part by a rights notation or a Creative Commons License present in this item record. All permission requests should be directed accordingly and not to the Sigma Repository. All submitting authors or publishers have affirmed that when using material in their work where they do not own copyright, they have obtained permission of the copyright holder prior to submission and the rights holder has been acknowledged as necessary.

Review Type

Abstract Review Only: Reviewed by Event Host

Acquisition

Proxy-submission

Date of Issue

2026-11-16

Click above link to access the slide deck.

Share

COinS
 

The Development, Feasibility and Credibility of Intra-Abdominal Pressure Measurement Techniques: A Scoping Review

Singapore

Purpose: Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are potentially life-threatening diseases, most of which are occult in occurrence, with complex and variable clinical symptoms. Intra-abdominal pressure (IAP) measurement has become a recognized practice in the field of critical care. However, the repeatability, safety, and credibility of these measurement techniques remain unclear. The aim of this study is to provide a comprehensive overview on emerging direct and alternative methods for intra-abdominal pressure (IAP) measurement techniques.

Methods: This was a scoping review study following Arksey and Malley's framework. The PubMed, EMBASE, Web of Science, EBSCO, Scopus and ProQuest databases were searched, and studies published between 2000 and 2023 inclusive were considered. All identified studies were reviewed by two reviewers through article title and abstract screening. Full-text articles were assessed based on the inclusion criteria. Original studies that reported on the development, feasibility and credibility of IAP measurement techniques were included.

Results: Forty-two of 9954 screened articles were included. IAP measurement techniques include three major categories: direct, indirect (including the transvesical, transgastric, transrectal, transfemoral vein and intravaginal methods) and less invasive measurement techniques (the abdominal wall tension measurement method, microwave reflectometry, the ultrasonographic method and the measurement system for pressurized vessels). Agreement analyses were performed in most studies, and some explored the safety, time expenditure and reproducibility of IAP measurement techniques.

Conclusion: Clinical data assessing the validation of new IAP measurement techniques or the reliability of established measurement techniques remain lacking. At present, there are still many shortcomings in direct and alternative methods for IAP measurement. Intrarater reliability of intravaginal transducers has not been evaluated, while the transrectal and transfemoral vein methods have not be proven to be feasible and credible. Abdominal wall tension method still need be standardized to obtain more reliable and repeatable evaluations. Transvesical method is the potentially most credibility and easy applicable technique fo